Our RadiantGUARD® double-sided "Premium" is approximately
5 mils thick (5 thousandths of an inch) and laser-perforated for
breathability.
Roll is 48 inches wide and 125 feet long for a total
of 500 square feet. Shipping weight per roll is 9 pounds.
We do not offer on-perforated (SOLID) versions of this
product.
If you require
non-perforated (SOLID), please see our 1,000 sq ft
rolls of "Ultima".
|
 |
RadiantGUARD® "Premium" is designed for
installations requiring stapling but it can also be used for installations over
the attic floor. If you require a stronger and heavier stapling version,
please see our "Ultima" radiant barrier.
RadiantGUARD® Benefits:
Class A / Class 1 Fire Rating
Non-toxic / non-carcinogenic
Environmentally safe
Fiber free
Does not require protective clothing or respirators to install
Durable and lightweight
Not affected by moisture or humidity
Easy to install and maintenance free
Made in the USA
Lowers heating and cooling costs year round
Interested in volume pricing on pallet quantities (48,000 square feet)?
Please email us via our CONTACT page.
View our foil insulation radiant
barrier installation instructions
| |
RadiantGUARD® Product Specifications & Comparisons
Double sided reflective 99% pure aluminum foil with polyethylene mesh
reinforced middle layer.
|
| |
|
STANDARD |
|
PREMIUM |
|
ULTIMA |
| Weight: |
|
14.1 lb M/sf |
|
13.4 lb M/sf |
|
24.6 lb M/sf |
| Tensile Strength: |
|
(ASTM D-882) |
|
(ASTM D-882) |
|
(ASTM D-882) |
| Machine Direction: |
|
14.1 lb/in width |
|
17.1 lb/in width |
|
80.4 lb/in width |
| Cross Direction: |
|
8.7 lb/in width |
|
11.4 lb/in width |
|
65.4 lb/in width |
| Mullen Burst Strength: |
|
22 psi |
|
40.6 psi |
|
160 psi |
| Flame Spread: |
|
15
(ASTM E-84-03) |
|
5
(ASTM E-84-91A) |
|
10
(ASTM E-84) |
| Smoke Development: |
|
5
(ASTM E-84-03) |
|
10
(ASTM E-84-91A) |
|
10
(ASTM E-84) |
| Fire Rating: |
|
Class A/Class 1
(ASTM E-84-03) |
|
Class A/Class
(ASTM E-84-91A) |
|
Class A/Class 1
(ASTM E-84) |
| Water Vapor Permeability: |
|
105G/m2/24hrs
(ASTM E-96 Method A) |
|
70G/m2/24hrs
(ASTM E-96 Method A) |
|
70G/m2/24hrs
(ASTM E-96 Method A) |
| Reflectivity: |
|
97%
(ASTM C-1371-98) |
|
97%
(ASTM C-1371-98) |
|
97%
(ASTM C-1371-98) |
| Emittance: |
|
3%
(ASTM C-1371-98) |
|
3%
(ASTM C-1371-98 |
|
3%
(ASTM C-1371-98) |
All RadiantGUARD® radiant barriers meet the Standard Specifications
for Sheet Radiant Barriers for Building Construction Applications ASTM C1313
and the State of California Insulation Standards.
|
|
|
|